145 - 145 |
Recent advances in new technologies and applications for molecular TEM Carragher B, Potter CS |
146 - 150 |
MRC2014: Extensions to the MRC format header for electron cryo-microscopy and tomography Cheng AC, Henderson R, Mastronarde D, Ludtke SJ, Schoenmakers RHM, Short J, Marabini R, Dallakyan S, Agard D, Winn M |
151 - 158 |
Site-specific labeling of proteins for electron microscopy Dambacher CM, Lander GC |
159 - 162 |
Protein domain mapping by internal labeling and single particle electron microscopy Ciferri C, Lander GC, Nogales E |
163 - 173 |
Evaluation of super-resolution performance of the K2 electron-counting camera using 2D crystals of aquaporin-O Chiu PL, Li XM, Li ZL, Beckett B, Brilot AF, Grigorieff N, Agard DA, Cheng YF, Walz T |
174 - 178 |
Asynchronous data acquisition and on-the-fly analysis of dose fractionated cryoEM images by UCSFImage Li XM, Zheng S, Agard DA, Cheng YF |
179 - 187 |
FEI's direct electron detector developments: Embarking on a revolution in cryo-TEM Kuijper M, van Hoften G, Janssen B, Geurink R, De Carlo S, Vos M, van Duinen G, van Haeringen B, Storms M |
188 - 195 |
Alignment of cryo-EM movies of individual particles by optimization of image translations Rubinstein JL, Brubaker MA |
196 - 203 |
The influence of frame alignment with dose compensation on the quality of single particle reconstructions Spear JM, Noble AJ, Xie Q, Sousa DR, Chapman MS, Stagg SM |
204 - 208 |
Automatic estimation and correction of anisotropic magnification distortion in electron microscopes Grant T, Grigorieff N |
209 - 215 |
Description and comparison of algorithms for correcting anisotropic magnification in cryo-EM images Zhao JH, Brubaker MA, Benlekbir S, Rubinstein JL |
216 - 221 |
CTFFIND4: Fast and accurate defocus estimation from electron micrographs Rohou A, Grigorieff N |
222 - 234 |
Visualization and quality assessment of the contrast transfer function estimation Sheth LK, Piotrowski AL, Voss NR |
235 - 244 |
Single-particle cryoEM analysis at near-atomic resolution from several thousand asymmetric subunits Passos DO, Lyumkis D |
245 - 254 |
A new protocol to accurately determine microtubule lattice seam location Zhang R, Nogales E |
255 - 261 |
Numerical geometry of map and model assessment Wriggers W, He J |
262 - 269 |
A focused ion beam milling and lift-out approach for site-specific preparation of frozen-hydrated lamellas from multicellular organisms Mahamid J, Schampers R, Persoon H, Hyman AA, Baumeister W, Plitzko JM |
270 - 278 |
Automated batch fiducial-less tilt-series alignment in Appion using Protomo Noble AJ, Stagg SM |
279 - 286 |
The Caltech Tomography Database and Automatic Processing Pipeline Ding HJ, Oikonomou CM, Jensen GJ |
287 - 296 |
Simultaneous determination of sample thickness, tilt, and electron mean free path using tomographic tilt images based on Beer-Lambert law Yan R, Edwards TJ, Pankratz LM, Kuhn RJ, Lanman JK, Liu J, Jiang W |
297 - 306 |
A fast cross-validation method for alignment of electron tomography images based on Beer-Lambert law Yan R, Edwards TJ, Pankratz LM, Kuhn RJ, Lanman JK, Liu J, Jiang W |
307 - 311 |
M-free: Mask-independent scoring of the reference bias Kunz M, Yu Z, Frangakis AS |