2247 - 2247 |
Instrumentation for Capillary Electrophoresis and Microchip Electrophoresis Garcia CD, Carrilho E |
2248 - 2252 |
Dual-wavelength recording, a simple algorithm to eliminate interferences due to UV-absorbing substances in capillary electrophoresis Seaux L, Van Houcke S, Dumoulin E, Fiers T, Lecocq E, Delanghe JR |
2253 - 2266 |
Microfluidics for the analysis of membrane proteins: How do we get there? Battle KN, Uba FI, Soper SA |
2267 - 2278 |
Coupling of fluorescence correlation spectroscopy with capillary and microchannel analytical systems and its applications Dong CQ, Ren JC |
2279 - 2291 |
Thermal lens microscopy as a detector in microdevices Cassano CL, Mawatari K, Kitamori T, Fan ZH |
2292 - 2308 |
Review of the CE-MS platform as a powerful alternative to conventional couplings in bio-omics and target-based applications Robledo VR, Smyth WF |
2309 - 2324 |
Recent advances in low-cost microfluidic platforms for diagnostic applications Coltro WKT, Cheng CM, Carrilho E, de Jesus DP |
2325 - 2332 |
Fast and versatile fabrication of PMMA microchip electrophoretic devices by laser engraving Gabriel EFM, Coltro WKT, Garcia CD |
2333 - 2345 |
Remote-controlled robotic platform ORPHEUS as a new tool for detection of bacteria in the environment Nejdl L, Kudr J, Cihalova K, Chudobova D, Zurek M, Zalud L, Kopecny L, Burian F, Ruttkay-Nedecky B, Krizkova S, Konecna M, Hynek D, Kopel P, Prasek J, Adam V, Kizek R |
2346 - 2352 |
Surface modification of PDMS microchips with poly(ethylene glycol) derivatives for mu TAS applications de Campos RPS, Yoshida IVP, da Silva JAF |
2353 - 2360 |
Induced hydraulic pumping via integrated submicrometer cylindrical glass capillaries Cao Z, Yobas L |
2361 - 2369 |
Improved high-speed capillary electrophoresis system using a short capillary and picoliter-scale translational spontaneous injection Zhang T, Fu JL, Fang Q |
2370 - 2377 |
Getting started with open-hardware: Development and control of microfluidic devices da Costa ET, Mora MF, Willis PA, do Lago CL, Jiao H, Garcia CD |
2378 - 2385 |
Rapid screening of the heterogeneity of DNA methylation by single-strand conformation polymorphism and CE-LIF in the presence of electro-osmotic flow Yu MH, Huang YC, Chang PL |
2386 - 2391 |
Nonaqueous capillary electrophoresis as separation technique to support metabolism studies by means of electrochemistry and mass spectrometry Roscher J, Faber H, Stoffels M, Oller OH, Happe J, Karst U |
2392 - 2400 |
Battery-powered portable instrument system for single-cell trapping, impedance measurements, and modeling analyses Tsai SL, Chiang Y, Wang MH, Chen MK, Jang LS |
2401 - 2407 |
Capacitance-to-digital: A single chip detector for capillary electrophoresis Drevinskas T, Kaljurand M, Maruska A |
2408 - 2411 |
12-Channel Peltier array temperature control unit for single molecule enzymology studies using capillary electrophoresis Craig DB, Reinfelds G, Henderson A |
2412 - 2416 |
A simple approach to compensate the suction caused by the electrospray ionization source in capillary electrophoresis-mass spectrometry systems do Lago CL, Vidal DTR, Francisco KJM, dos Santos VB |
2417 - 2419 |
Paper microfluidic-based enzyme catalyzed double microreactor Ferrer IM, Valadez H, Estala L, Gomez FA |