화학공학소재연구정보센터
Journal of Chemical and Engineering Data, Vol.51, No.5, 1624-1628, 2006
Experimental vapor-liquid equilibria for the carbon dioxide plus octane and carbon dioxide plus decane systems
The vapor-liquid equilibria (VLE) for the carbon dioxide + octane, and carbon dioxide + decane systems were measured from ( 322 to 372) K and ( 319 to 372) K, respectively. The measurements were carried out with a static-type apparatus connected online to a gas chromatograph. A good agreement was found between the experimental measurements for the studied systems and those reported in the literature at 348 and 344 K for the carbon dioxide + octane and carbon dioxide + decane systems, respectively. Both systems were correlated using the Peng-Robinson equation of state with classical and Wong-Sandler mixing rules. The best VLE representation was obtained using the Wong-Sandler mixing rule with an absolute average deviation less than 1.8% and 0.0020 mole fraction for pressure and equilibrium compositions, respectively.