KAGAKU KOGAKU RONBUNSHU, Vol.27, No.3, 403-406, 2001
The thermal degradation rate constant of mixed plastics
The thermal degradation rate constant of plastics containing polypropylene, polyethylene and polystyrene was analysed by using the distributed activation energy model. The values of activation energy E and frequency factor ko were widely distributed and differed between samples tested. The ko value was well correlated with E. It is extremely important to take the E distribution into consideration in estimating the weight of un-volatilized matter accumulated in the waste plastics degradation reactor.