Oil Shale, Vol.20, No.4, 501-509, 2003
High-temperature corrosion resistance of the austenitic steels in the presence of chlorine-containing on-tube deposits
High-temperature corrosion resistance of a number of boiler steels was tested experimentally in laboratory and industrial conditions in the presence of chlorine-containing external deposits. Empirical kinetic equations for calculation of corrosion depth depending on operational time and temperature were established, and the dependence of corrosion resistance of the austenitic steels on the alloying elements ratio Ni/Cr was analyzed.