화학공학소재연구정보센터
Chinese Journal of Chemical Engineering, Vol.20, No.5, 837-842, 2012
Continuous Separation of Cesium Based on NiHCF/PTCF Electrode by Electrochemically Switched Ion Exchange
Nickel hexacyanoferrate (NiHCF) film was synthesized on porous three-dimensional carbon felt (PTCF) substrate by repetitious batch chemical depositions, and the NiHCF/PTCF electrode was used as electrochemically switched ion exchange (ESIX) electrode in a packed bed for continuous separation for cesium ions. The morphologies of the prepared electrodes were characterized by scanning electron microscopy and the effects of solution concentration on the ion-exchange capacity of the electrodes were investigated by cyclic voltammetry technique. Cycling stability and long-term storage stability of NiHCF/PTCF electrodes were also studied. The NiHCF/PTCF electrodes with excellent ion-exchange ability were used to assemble a diaphragm-isolated ESIX reactor for cesium separation. Continuous separation of cesium and regeneration of NiHCF/PTCF electrode based on the diaphragm-isolated reactor were performed in a laboratory-scale two-electrode system.