Chinese Journal of Chemical Engineering, Vol.20, No.6, 1039-1046, 2012
A Review for Model Plant Mismatch Measures in Process Monitoring
Model is usually necessary for the design of a control loop. Due to simplification and unknown dynamics, model plant mismatch is inevitable in the control loop. In process monitoring, detection of mismatch and evaluation of its influences are demanded. In this paper several mismatch measures are presented based on different model descriptions. They are categorized into different groups from different perspectives and their potential in detection and diagnosis is evaluated. Two case studies on mixing process and distillation process demonstrate the efficacy of the framework of mismatch monitoring.