Journal of Chemical and Engineering Data, Vol.40, No.4, 837-839, 1995
Liquid-Liquid Equilibria for Triton X-100 Plus Water as a Function of Pressure
Liquid-liquid equilibria were measured at pressures of 0.0, 50.0, 100.0, and 150.0 bar for Triton X-100 + water. The lower critical solution temperature of the Triton X-100 + water binary system is about 339 K at all pressures investigated.