Energy and Buildings, Vol.45, 211-218, 2012
Performance evaluation of a building integrated semitransparent photovoltaic thermal system for roof and facade
In this paper, analytical expressions have been derived for room air temperature of building integrated semitransparent photovoltaic thermal (BISPVT) and building integrated opaque photovoltaic thermal (BIOPVT) systems each integrated to the roof of a room with and without air duct. Comparative studies have also been carried out between BISPVT and BIOPVT system each integrated to the facade and roof of a room with and without air duct for the cold climatic conditions of Srinagar, India. However. the present thermal model is also valid for different climatic conditions. It is observed that there are maximum (18.0 degrees C) and minimum (2.3 degrees C) rise in room air temperature for semitransparent photovoltaic thermal (SPVT) roof without air duct and opaque photovoltaic thermal (OPVT) facade with air duct respectively. Further, on the basis of sensitive ana(C) 2011 Elsevier B.V. All rights reserved.