Energy Conversion and Management, Vol.79, 487-497, 2014
Numerical and experimental evaluation of fly ash collection efficiency in electrostatic precipitators
This paper evaluates experimentally and numerically the influence of different geometrical and operating parameters of a single stage wire-duct electrostatic precipitators (WDEP) on its fly ash collection efficiency. The governing equations are solved under dust loading conditions using the finite element method (FEM) and a modified method of characteristics (MMC). In addition, a proto-type design that represents a WDEP was successfully designed and fabricated at the research institute of KFUPM (RI-KFUPM). The experiments were carried out under laboratory conditions where the WDEP was made of Plexiglas with a length of 2 m, height of 1 m, wire-to-collecting plate spacing of 0.2-0.3 m, and an inter-electrode (wire-to-wire) spacing of 0.16-0.21 m. Smoke of fired coal was used as a source of seed particles of PM10 category (with 75-80% of particles lying below 10 mu m). An indication of the effectiveness of the numerical approach was carried out through a comparison of computed results as well as presently and previously obtained experimental data. (C) 2013 Elsevier Ltd. All rights reserved.