화학공학소재연구정보센터
Geothermics, Vol.31, No.5, 525-543, 2002
Measurement and use of the vertical gravity gradient in correcting repeat microgravity measurements for the effects of ground subsidence in geothermal systems
Changes in mass resulting from production and reinjection in geothermal fields can be monitored using repeat microgravity measurements. The measured changes in gravity, however, need to be corrected for the effects of any exploitation-induced ground subsidence. The correction required at each measurement point is the product of the amount of ground subsidence and the vertical gravity gradient at that point. Measurements of the gravity gradient, made using a portable tower, show that it varies from place to place depending mainly on the local topography. Measured gradients in areas of high subsidence rate, range between -276 and -339 mugal/m at 30 sites in the Wairakei-Tauhara field and between -296 and -321 mugal/m at nine sites in the Ohaaki field (New Zealand), These values are similar to those used previously. At 37 sites measured in the Yanaizu-Nishiyama field (Japan) the gradient varied between -244 and -352 mugal/m. Measurements at six sites showed no significant change in gravity gradient with height above the ground surface; a single value for the gradient can therefore be used at each site to correct for the gravitational effect of any ground movement. Calculations show the effects on the vertical gravity gradient of groundwater level variations, mass changes associated with the ground subsidence, and reservoir mass changes are negligible at Wairakei. (C) 2002 CNR. Published by Elsevier Science Ltd. All rights reserved.