Geothermics, Vol.49, 76-82, 2014
Pilot testing of handling the fluids from the IDDP-1 exploratory geothermal well, Krafla, NE Iceland
Material tests and scrubbing experiments were carried out at the IDDP-1 well in the Krafla geothermal field in Iceland. The 450 degrees C superheated steam contained acid gas (approx. 90 mg/kg HCl and 7 mg/kg HF) and was highly corrosive when it condensed making it unsuitable for utilization without scrubbing. The acid gas could effectively be scrubbed from the steam with water. The steam contained gasous sulfur compond (80-100 mg/kg S), which could only be scrubbed from the steam with alkaline water. The steam contained both silica dust and dissolved silica which was effectively washed from the steam with wet scrubbing. Experiments on corrosion and erosion resistance of metals and alloys were problematic to run because of equipment clogging by silica dust. (C) 2013 Elsevier Ltd. All rights reserved.