Journal of Colloid and Interface Science, Vol.368, 512-520, 2012
In situ kinetic study of zinc sulfide activation using a quartz crystal microbalance with dissipation (QCM-D)
We have studied the activation kinetics of zinc sulfide (ZnS) using silver as an activator by a quartz crystal microbalance with dissipation (QCM-D). The zinc sulfide coating on QCM-D sensor was shown to have similar crystallographic structure, composition, and surface properties as nature sphalerite through the characterization of X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), and xanthate adsorption measurement using QCM-D. The activation of ZnS sensor by silver was confirmed by the mass increase in ZnS sensor coupled with subsequent xanthate adsorption during QCM-D measurement, the change of surface wettability, and the presence of Ag2S on the surface. Two distinct stages on the silver uptake vs. time curve were identified and fitted well by a logarithmic function for the initial stage and a parabolic law in the later stage, which agrees with the two-stage zinc-silver reaction kinetics reported previously. Argon sputtering followed by XPS measurement on the ZnS surface demonstrated the penetration of silver into the bulk ZnS after activation. The present study is the first of its kind to apply the QCM-D technique to investigate sphalerite activation, which introduces a new in situ approach to investigate surface adsorption and activation in many mineral processes and surface modifications. (C) 2011 Elsevier Inc. All rights reserved.