화학공학소재연구정보센터
Journal of Hazardous Materials, Vol.231, 49-56, 2012
Non-chromatographic mercury speciation and determination in wine by new core-shell ion-imprinted sorbents
In this study new Hg(II) core-shell imprinted sorbents (Hg(II)-IIPs) were prepared and tested for speciation and determination of Hg in wine. The silica gel, chemically modified with 3-(trimethoxysilyl)propyl methacrylate (TSPM) was used as supporting material. The Hg(II)-imprinted polymer layer was grafted by copolymerization of methacrylic acid and trimethylolpropane trimethacrylate in the presence of Hg(II) complexes with two different chelating agents: 1-pyrrolidinedithiocarboxylic acid (P(PDC-Hg)/SiG) and 1-(2-thiazolylazo)-2-naphthol (P(TAN-Hg)/SiG). High selectivity and fast kinetics of processes of sorption and desorption for Hg(II) were found by using P(PDC-Hg)/SiG. Recovery experiments performed for selective determination of inorganic mercury in wines showed that the interfering organic matrix did not influence the extraction efficiency. Column solid phase extraction scheme was developed for the determination and speciation of Hg in wines. The limit of detection (LOD) achieved for inorganic mercury determination in wine samples is 0.02 mu g L-1 (3 sigma), measured by CV AAS. The relative standard deviation varied in the range 6-11% at 0.05-2 mu g L-1 Hg levels. The sorbents showed high mechanical and chemical stability and extraction efficiency has not changed after more than 50 sorption/desorption cycles. (C) 2012 Elsevier B.V. All rights reserved.