Materials Science Forum, Vol.510-511, 870-873, 2006
Thermopneumatic-actuated polydimethylsiloxane (PDMS) microfluidic system
We propose a new PDMS microfluidic system including microvalves and a micropump that are easily integrated on the same substrate with the same process steps. The pumping rate of the fabricated microfluidic system was measured under various frequency and duty-ratio of applied power. The maximum pumping rate of about 26 nl/min is measured under the duty ratio of 1 % at 2 Hz of the applied pulse voltage. The dynamic response of the microvalve in the microfluidic system is measured under the on/off alternation with the applied power of 100 mW.