화학공학소재연구정보센터
Korean Journal of Materials Research, Vol.19, No.1, 44-49, January, 2009
Enzyme-Conjugated CdSe/ZnS Quantum Dot Biosensors for Glucose Detection
E-mail:
Conjugated nanocrystals using CdSe/ZnS core/shell nanocrystal quantum dots modified by organic linkers and glucose oxidase (GOx) were prepared for use as biosensors. The trioctylphophine oxide (TOPO)-capped QDs were first modified to give them water-solubility by terminal carboxyl groups that were bonded to the amino groups of GOx through an EDC/NHS coupling reaction. As the glucose concentration increased, the photoluminescence intensity was enhanced linearly due to the electron transfer during the enzymatic reaction. The UV-visible spectra of the as-prepared QDs are identical to that of QDs-MAA. This shows that these QDs do not become agglomerated during ligand exchanges. A photoluminescence (PL) spectroscopic study showed that the PL intensity of the QDs-GOx bioconjugates was increased in the presence of glucose. These glucose sensors showed linearity up to approximately 15 mM and became gradually saturated above 15 mM because the excess glucose did not affect the enzymatic oxidation reaction past that amount. These biosensors show highly sensitive variation in terms of their photoluminescence depending on the glucose concentration.
  1. Bawendi MG, Steigerwald ML, Brus LE, Annu. Rev. Phys. Chem., 41, 477 (1990)
  2. Alivisatos AP, Science, 271(5251), 933 (1996)
  3. Murray CB, Norris DJ, Bawendi MG, J. Am. Chem. Soc., 115, 8706 (1993)
  4. Sung YM, Lee YJ, Park KS, J. Am. Chem. Soc., 128(28), 9002 (2006)
  5. Dabbousi BO, Rodriguezviejo J, Mikulec FV, Heine JR, Mattoussi H, Ober R, Jensen KF, Bawendi MG, J. Phys. Chem. B, 101(46), 9463 (1997)
  6. Bruchez M, Moronne M, Gin P, Weiss S, Alivisatos AP, Science, 281(5385), 2013 (1998)
  7. Alivisatos AP, Nature Biotechnol., 22, 47 (2004)
  8. Michalet X, Pinaud FF, Bentolila LA, Tsay JM, Doose S, Li JJ, Sundaresan G, Wu AM, Gambhir SS, Weiss S, Science, 307, 538 (2005)
  9. Liu H, Hu N, Electroanal., 19, 884 (2007)
  10. Huang CP, Ki YK, Chen TM, Biosens. Bioelectron., 22, 1835 (2007)
  11. Zhang S, Wang N, Yu H, Niu Y, Sun C, Bioelectrochem., 67, 15 (2005)
  12. Sung YM, Park KS, Lee YJ, Chae WS, Song YW, Electrochem. Solid State Lett., 8(2), H24 (2005)
  13. Arata HF, Low P, Ishizuka K, Bergaud C, Kima B, Noji H, Fujita H, Sens. Actuator B-Chem., 117, 339 (2006)
  14. Sapsford KE, Pons T, Medintz IL, Mattoussi H, Sensors, 6, 925 (2006)
  15. Cordes DB, Gamsey S, Singaram B, Angew. Chem. Int. Ed., 45, 3829 (2006)
  16. Yildiz I, Tomasulo M, Raymo FM, Proc. Natl. Acad. Sci. USA, 103, 11457 (2006)
  17. Chan WCW, Nie SM, Science, 281(5385), 2016 (1998)
  18. Peng ZA, Peng XG, J. Am. Chem. Soc., 123(1), 183 (2001)
  19. Lee YJ, Kim TG, Sung YM, Nanotechnol., 17, 3539 (2006)
  20. Patel N, Davies MC, Hartshorne M, Heaton RJ, Roberts CJ, Tendler SJ, Williams PM, Langmuir, 13(24), 6485 (1997)
  21. Pickup JC, Hussain F, Evans ND, Rolinski OJ, Birch DJS, Biosens. Bioelectron., 20, 2555 (2005)
  22. Xie H, Tan XL, Gao Z, Front. Biosci., 10, 1797 (2005)