- Previous Article
- Next Article
- Table of Contents
Korean Journal of Materials Research, Vol.17, No.5, 289-292, May, 2007
와류 유량센서용 압전 바이몰프의 온도변화에 따른 특성
Characteristics of Temperature Variation to the Piezoelectric Bimorph for Vortex Flowmeter
E-mail:
Although piezoelectric bimorph that is using as the sensor in medical and industrial measurement has large displacement, it has problems including efficiency in generating force, energy convergence, and response. Its application is being limited based on the change in resonance frequency with temperature. In this study, to overcome the disadvantages, PZT piezoelectric ceramics was prepared and produced a parallel type piezoelectric bimorphs. In addition, by using the finite element method. the configuration of piezoelectric bimorph was designed and the displacement of the bimorph based on applied electric pressure and the wave pattern were measured. By analyzing the resonance characteristics of the bimorph in the temperature range of , an attempt was made to study the operational characteristics and temperature reliability of vortex flowmeter sensor. As a result, the resonance frequency of the bimorph was gradually increased with the temperature from . The deflection of the bimorph was found to strongly depend on both the applied electric field waveform and the environmental temperature.
- Uchino K, Piezoelectric/Electrostrictive Actuator, Morikita Publishers, Tokyo, Japan (1986) (1986)
- Patel ND, Nichison PS, Am. Ceram. Soc. Bull., 65(5), 783 (1986)
- Jaffe B, Cook WR, Jaffe H, Piezoelectric ceramics, p.140, Academic Press, London (1971) (1971)
- Im J, Roh Y, Kim S, J. Kor. Ceram. Soc., 34(4), 337 (1997)