Chemical Engineering Journal, Vol.264, 479-486, 2015
Simulation of the heterogeneous semi-dry flue gas desulfurization in a pilot CFB riser using the two-fluid model
Simi-dry flue gas desulfurization (FGD) in a pilot circulating fluidized bed (CFB) reactor was studied by the CFD method. Heterogeneous hydrodynamics and desulfurization reaction were simulated in a three-dimensional domain of the CFB riser. Euler-Euler approach was adopted and the O-S drag model was utilized for the unsteady gas-solid two-phase flow, which achieved the typical core-annulus structure of both the particle concentration and the particle velocity. The collision coefficient (e) was selected by comparing with the experimental data of the solid volume fraction. The desulfurization was described by the continuous conversion model and the liquid film thickness equation for interphase mass transport was modified to avoid "divided by zero". Detailed analysis figured out that the water mass fraction in the particle phase played a significant role in the desulfurization. The sorbent dissolving might be a controlling step when the water mass fraction was very small, and should be taken into consideration rather than neglected. Operating parameters were discussed for their impact on the desulfurization efficiency. Computational results showed that the jet water flow rate was the most significant parameter as the circulating solid mass flow rate followed closely behind, suggesting that uniform water jetting will be the most improving method. (C) 2014 Elsevier B.V. All rights reserved.
Keywords:Semi-dry FGD;Circulating fluidized bed;3D transient simulation;Heterogeneous drag model;Modified liquid film thickness equation;Controlling step