화학공학소재연구정보센터
Journal of Materials Science, Vol.29, No.20, 5449-5454, 1994
Nonstable Structure of High-Chromium and High-Nitrogen Iron-Based Alloy
The structure of an iron alloy containing 18% Cr and 0.72% N after different treatments was studied by X-ray and electron microscopy. It was shown that the gamma-structure of the alloy after quenching is non-stable at all temperatures of isothermal holding, especially at high tempering temperatures. The C-shaped hypothetical diagram of the alloy was constructed from the experimental results.