International Journal of Hydrogen Energy, Vol.40, No.16, 5739-5748, 2015
Slow strain rate tensile and fatigue properties of Cr-Mo and carbon steels in a 115 MPa hydrogen gas atmosphere
Slow strain rate tensile (SSRT) tests were performed using smooth specimens of two types of steels, the Cr-Mo steel, JIS-5CM435, which has a tempered, martensitic microstructure, and the carbon steel, JIS-SM490B, which has a ferrite/pearlite microstructure. The tests were carried out in nitrogen gas and hydrogen gas, under a pressure of 115 MPa at three different temperatures: 233 K, room temperature and 393 K. In nitrogen gas, these steels exhibited the so-called cup-and-cone fracture at every temperature. In contrast, surface cracking led to a marked reduction in ductility in both steels in hydrogen gas. Nonetheless, even in hydrogen gas, JIS-SCM435 exhibited some reduction of area after the stress-displacement curve reached the tensile strength (TS), whereas JIS-SM490B demonstrated little, if any, necking in hydrogen gas. In addition, tension-compression fatigue testing at room temperature revealed that these steels show no noticeable degradation in fatigue strengths in hydrogen gas, especially in the relatively long-life regime. Considering that there was little or no hydrogen-induced degradation in either the TS or the fatigue strength in JIS-SCM435, it is suggested that the JIS-SCM435 is eligible for safety factor-based fatigue limit design for hydrogen service under pressures up to 115 MPa. Copyright (C) 2015, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
Keywords:Hydrogen embrittlement;Slow strain rate tensile test;Fatigue test;Cr-Mo steel;Carbon steel;High pressure hydrogen gas