Journal of Canadian Petroleum Technology, Vol.54, No.2, 81-84, 2015
Heating Strategies for Steam-Assisted-Gravity-Drainage-Startup Phase
The work introduces an analytical model to predict startup duration for steam circulation by electromagnetically heating with either induction (medium) or radio- frequency (RF) ranges. The results obtained reveal that induction slightly decreases startup time (ranging from 3 to several months' time) for frequencies smaller than 10 kHz, and it can reduce startup time to 30% of original steam circulation for 100-kHz frequency.