화학공학소재연구정보센터
Materials Chemistry and Physics, Vol.158, 74-81, 2015
Comparison of tribological and electrochemical properties of TiN, CrN, TiAlN and a-C:H coatings in simulated body fluid
TiN, CrN, TiAlN and a-C:H coatings have been used for wear reduction, but a thorough comparison of their erosion and abrasion characteristics in simulated body fluid (SBF) has never been reported in existent literature. In this study, the tribological and electrochemical performance of these coatings in SBF was investigated and compared. As a result, the TiAlN coating presented the worst tribological and electrochemical properties because of abundant products from hydration. On the contrary, due to the generation of a favorable tribochemical product (Cr2O3), the CrN coating exhibited superior characteristics of tribology and electrochemistry. The a-C:H coating also showed outstanding corrosion resistance, but premature delamination occurred in aqueous environment which might limit its application. Thus, the CrN coating was found to be the most favorable protection coating in SBF from a comprehensive viewpoint. (C) 2015 Elsevier B.V. All rights reserved.