Chemical Engineering and Processing, Vol.113, 86-93, 2017
Control of a reactive distillation column with double reactive sections for two-stage consecutive reactions
In this study, the control performance of a reactive distillation column with double reactive sections is evaluated. The reactions taking place in the column are two-stage consecutive reversible liquid-phase reactions. A hypothetical ideal reaction system is selected as case study. Different control structures including temperature and/or composition control loops are developed and tested for different load disturbances. The closed loop results of different control structures demonstrate that a workable control structure should include direct control of compositions. A control structure with two temperature controllers and two composition controllers provides an effective control for the column with double reactive sections. (C) 2016 Elsevier B.V. All rights reserved.
Keywords:Reactive distillation column;Two-stage consecutive reactions;Double reactive sections;Process control