Electrochimica Acta, Vol.233, 151-166, 2017
Is niobium more corrosion-resistant than commercially pure titanium in fluoride-containing artificial saliva?
In this work, commercially pure niobium (c. p. Nb) was selected to study its electrochemical behaviour in artificial saliva with several concentrations of fluoride ions (F ) over a range of 0-0.24M. The chemical nature of passive layers on surface was characterised with x-ray photoelectron spectroscopy (XPS). The changes in surface topography due to F -inducedcorrosion were examined with scanning electron microscopy (SEM). For comparison, commercially pure titanium (c. p. Ti) was also investigated under identical conditions. Both c. p. Nb and c. p. Ti exhibit very good corrosion resistance in artificial saliva without F or with a low level of F showing a low passive current density (j(pass)) andhigh polarisation resistance (Rp). However, as the F concentration increases, c. p. Nb demonstrates a significantly greater corrosion resistance due to its stable passive film (mainly Nb2O5) with a thickness of several nanometres, showing a much lower j(pass) and higher Rp, with both values differing from those of c. p. Ti by over one order of magnitude. Significant differences in the corrosion behaviour between c. p. Nb and c. p. Ti can be understood from the thermodynamic perspective and the propensity of oxide dissolution. The advantage of niobium over titanium merits attention, as the c. p. Nb and Nb-based alloys are promising for further applications in dental prosthesis fabrication. (C) 2017 Elsevier Ltd. All rights reserved.