Fuel Processing Technology, Vol.171, 232-247, 2018
Combustion measurements of type-1 pulverized coal flames operating under oxy-fired conditions
The present study addresses the impact of oxy-fired conditions on type-1 flames generated by an oxidant-staged burner operating with pre-dried lignite and applying wet flue-gas recirculation. Investigations were carried out in a laboratory facility where the combustion takes place in a furnace with a rated capacity of 0.40 MWth. In-flame measurements were performed for oxy-fired conditions operating at three levels of secondary swirl number (1.15, 1.65, and 2.05), while overall O-2 fraction upstream of the burner in oxy-firing was kept at 31 vol %. One air -fired condition at 1.65 secondary swirl number was also investigated. Measurements of local gas temperature and gas species concentrations were performed using standard water-cooled probes with focus on the near burner region. Results showed evidence of radial flame stratification consistent with gradual O-2 admixing to the central fuel jet. Lower temperatures on the flame axis were obtained under oxy-fired condition. In the same region, as a result of CO2 dissociation and/or gasification reactions by water vapor and CO2, higher CO concentrations were also monitored, which contributed to lower temperatures. Experimental data also suggested great potential for NO abatement through flame stratification due to type-1 flame pattern.