화학공학소재연구정보센터
Chemical Engineering Journal, Vol.352, 241-246, 2018
A rapid paper-based detection system for determination of human serum albumin concentration
A rapid analytical platform composed of a paper-based chip (mu PB-Chip) and a small analytic box is developed to determine the concentration of human serum albumin (HSA). In this study, a Bromocresol Green (BCG) reagent is dropped into the reaction area of the mu PB-Chip, and the HSA concentration was derived from the R (red) value intensity of the albumin-BCG complex formed after a reaction process at 37 degrees C for 12 min. The effectiveness of the developed method is displayed using albumin concentrations ranging from 0 to 5 g/dL in HSA control samples. The measurement results acquired from 36 volunteer patient's HSA samples are presented to be in good consistency with those obtained utilizing a conventional assay technique (R-2 = 0.9912). Ultimately, the results show that the developed platform provides a convenient, economical and dependable method for HSA concentration detection.