화학공학소재연구정보센터
Journal of Solar Energy Engineering-Transactions of The ASME, Vol.121, No.4, 207-209, 1999
The feasibility of using a septic tank as a heat source for geothermal heat pumps
A geothermal hear pump (GHP) system with three ground coils was installed in a residence in northern Idaho with a portion of the ground heat exchanger wrapped around the residential septic tank. The septic coil provided a significant portion of the heating for the residence over the heating season. There was no evidence of the septic tank freezing up or failing to properly function. Utilizing a septic tank as a heat source for GHP systems is feasible design option if the septic tank is used on a full-time basis. However, the tank should be surrounded on all sides by a large amount of soil and/or insulated from the ground surface to ensure that ground temperatures near the tank remain warm during the winter.