화학공학소재연구정보센터
Renewable Energy, Vol.131, 1208-1225, 2019
Power-to-load balancing for heaving asymmetric wave-energy converters with nonideal power take-off
The aim of this paper is to maximize the power-to-load ratio for asymmetric wave energy converters undergoing heave motion. Linear hydrodynamic theory is used to calculate bounds of the expected time averaged power (TAP) and corresponding surge-restraining force, pitch-restraining torque, and power take-off (PTO) control force with the assumption of sinusoidal displacement. This paper formulates an optimal control problem to handle an objective function with competing terms in an attempt to maximize power capture while minimizing structural and actuator loads in regular and irregular waves. Penalty weights are placed on the surge-restraining force, pitch-restraining torque, and PTO actuation force, thereby allowing the control focus to concentrate on either power absorption or load mitigation. The penalty weights are used to control peak structural and actuator loads that were found to curb the additional losses in power absorption associated with a nonideal PTO. Thus, in achieving these goals, a per-unit gain in TAP would not lead to a greater per-unit demand in structural strength, hence yielding a favorable benefit-to-cost ratio. Demonstrative results for "The Berkeley Wedge" in the form of output TAP, reactive TAP needed to drive WEC motion, and the amplitudes of the surge-restraining force, pitch restraining torque, and PTO control force are shown. (C) 2017 Published by Elsevier Ltd.