화학공학소재연구정보센터
Energy Sources Part A-recovery Utilization and Environmental Effects, Vol.41, No.17, 2083-2093, 2019
Describing a strategy to estimate the CO2-heavy oil minimum miscibility pressure based on the experimental methods
To measure MMP, slim tube method is time consuming, especially for heavy oils. In this study, a strategy is considered to measure the MMP in one of the Iranian heavy oil reservoirs. The strategy steps were done through; partial data of slim tube, coupling numerical model (CNM), full slim tube, and VIT test. The results showed that CNM technique with two experimental data obtains the MMP value faster than running a full slim tube with low error result. However, VIT determined MMP faster and its results illustrated that miscibility pressure for heavy oil occurs at zero IFT, unlike light oils.