화학공학소재연구정보센터
Chemie Ingenieur Technik, Vol.91, No.8, 1147-1151, 2019
Nachweis und Verfolgung von Membran-FoulingDetection and Tracking of Membrane Fouling
Membrane fouling is a negative contamination effect: compounds in the feed solution settle on the membrane surface or in the pores, limiting the efficiency and separation performance of the membranes. This effect occurs for different membrane types such as reverse osmosis, ultra-, nano- and microfiltration membranes. A method is presented how membrane fouling can be identified and tracked based on the zeta potential calculated from flow measurements.