Applied Energy, Vol.47, No.4, 341-354, 1994
Design and Performance-Characteristics of a Parabolic-Trough Solar-Collector System
A comparison of the advantages and disadvantages of concentrating collectors against conventional flat-plate collectors are presented. This is followed by the design of a parabolic-trough solar-collector system, due consideration having been given to collector-aperture and rim-angle optimisation, together with the receiver-diameter selection. The collector characteristic curve gives a test slope of 0.441 and a test intercept equal to 0.642. The value of the test slope differs considerably from the initially predicted value : this is attributed to the heat losses from the receiver support brackets. Subsequent allowance for these losses is presented : this reduces the difference from 24.9% to 5.7%. Other tests are presented, including the determination of the collector’s incidence-angle modifier, time constant and acceptance angle.