화학공학소재연구정보센터
Propellants Explosives Pyrotechnics, Vol.25, No.2, 49-53, 2000
Test setup for instrumented initiation tests
The initiation threshold of fragment impact on explosives was tested with single and double fragment impacts with zero and defined small rime differences at constant 40 mm impact distance against confined Composition B charges. Reaction levels can be described by the debris sizes of the casing, respectively of the confinement. Much more distinctively, these results can be analyzed more in detail by the pressure profiles measured with in-situ pressure gauges.