화학공학소재연구정보센터
Turkish Journal of Chemistry, Vol.23, No.3, 285-291, 1999
Supercritical CO2 extraction of ethanol
Extraction of ethanol was studied from both synthetic ethanol solution and fermentation broth using supercritical CO2 in an extraction apparatus in ranges of 313 to 333 K and 80 to 160 atmospheres, for varying extraction times. The experimental system consists mainly of four parts: a CO2 storage system, a high-pressure liquid primp, an extractor and a product collection unit. Samples were analyzed by gas chromatography. Effects of temperature, pressure, extraction time, initial ethanol concentration and consecutive solvent feeding on extraction yield were investigated. It Mras found that increasing the initial ethanol concentration and extraction pressure and decreasing the extraction temperature increased the extraction yield. In addition, it was observed that consecutive solvent feeding affected the extraction yield positively. With the Box-Wilson experimental design method, optimum extraction conditions in a batch system for 15% (v/v) ethanol solution were found to be 313 K, 133 atmospheres and 30 minutes. Extraction yields were found to be 5.8 % for one-step and 19.2 % for three-step extraction of fermentation broth.