Biotechnology Progress, Vol.19, No.1, 14-20, 2003
Heat inactivation of mammalian cell cultures for biowaste kill system design
A biowaste kill system was implemented to treat biological waste generated from a clinical manufacturing and R&D antibody facility. To confirm that design parameters of this continuous decontamination system are sufficient to inactivate mammalian cell culture waste, bench-scale experiments were conducted. The biowaste kill system heat inactivates mammalian cell cultures before they are piped to a neutralization tank and subsequently released to the sewage system. Heat inactivation of cells is accomplished by exposing cells to 80 degreesC for 3 min. Small-scale heat inactivation studies were performed on CHO, 293-HEK, and hybridoma cells. Cells at 1 x 10(6) cells/mL or 1 x 10(7) cells/mL were exposed to 37, 60, 70, or 80 degreesC for 0, 30, 60, and 120 s. Viability based on trypan blue exclusion method and ability to proliferate was assessed after exposure to heat. Data suggest that exposure of cells to 80 degreesC for 60 s is sufficient to inactivate these cultures before they are released to the sewage system.