화학공학소재연구정보센터
Energy and Buildings, Vol.35, No.4, 413-415, 2003
A simple method to determine the specific heat capacity of thermal insulations used in building construction
A simple transient test using the widespread heat flow meter apparatus (HFM) for thermal conductivity measurements is presented by which the specific heat capacity of thermal insulation materials, used in building construction can be determined with sufficient accuracy. The measured temperature evolution on specific sites of the specimens is evaluated numerically by the system identification technique.