International Journal of Heat and Mass Transfer, Vol.46, No.12, 2279-2290, 2003
Mist/steam cooling by a row of impinging jets
Mist/steam cooling has been studied to augment internal steam-only cooling for advanced turbine systems. Water droplets generally less than 10 mum are added to 1.3 bar steam and injected through a row of four round jets onto a heated surface. The Reynolds number is varied from 7500 to 22,500 and the heat flux varied from 3.3 to 13.4 kW/m(2). The mist enhances the heat transfer along the stagnation line and downstream wanes in about 3 jet diameters. The heat transfer coefficient improves by 50-700% at the stagnation line for mist concentrations 0.75-3.5% by weight. Off-axis maximum cooling occurs in most of the mist/steam flow but not in the steam-only flow. CFD simulation indicates that this off-axis cooling peak is caused by droplets' interaction with the target walls. (C) 2003 Elsevier Science Ltd. All rights reserved.