Journal of Applied Polymer Science, Vol.89, No.9, 2496-2501, 2003
Study on thermoplastic polyurethane/polypropylene (TPU/PP) blend as a blood bag material
Blends with different ratios of thermoplastic polyurethane/polypropylene (TPU/PP) were prepared by melt mixing using an internal Haake mixer. Properties of the blends were investigated using SEM micrographs of cryo-fractures and measurement of the mechanical strength, water absorption, cell culture, and platelet adhesion in vitro tests, which were compared with those of PVC blood bags. The effect of the addition of the ethylene-vinyl acetate (EVA) copolymer on the TPU/PP blend properties was investigated. The results indicated that a TPU/PP/EVA = 80/20/5 blend can be used as a new blood bag material. It was observed that the blend is homogeneous with higher mechanical strength than that of the commercial PVC blood bag. This blend also showed a compatible cell response in contact with L929 fibroblast cells and fewer tendencies to interaction with platelets compared to the PVC blood bag. Although the blends were immissible and no chemical reaction at the interface could be found, the blood compatibility of the blends were improved. (C) 2003 Wiley Periodicals, Inc.