화학공학소재연구정보센터
Desalination, Vol.166, No.1-3, 223-230, 2004
Heat-transfer film coefficients of falling film horizontal tube evaporators
The film thickness distribution and average thickness outside a horizontal test tube were measured with a film-thickness meter. The effects of liquid load, evaporation boiling point, temperature difference and tube diameter on the film thickness, the waving intensity and, as a result, the heat-transfer film coefficients outside the horizontal tube were studied. Experiments of the heat-transfer coefficient of horizontal-tube evaporation were conducted with various operation parameters. Equations for the evaporation heat-transfer coefficient were set up by regression of experimental data. The conclusion was made that when 200