화학공학소재연구정보센터
Journal of Membrane Science, Vol.240, No.1-2, 159-166, 2004
Removal of pollutants from indoor air using zeolite membranes
MFI-type zeolite membranes prepared by liquid phase hydrothermal synthesis on tubular commercial supports were used to remove model pollutants n-hexane, formaldehyde and benzene present at very low concentration levels (2-230 ppmv) in indoor air. The influence of several operating parameters was studied both in batch and continuous separation experiments. Depending on the operation conditions, permeation C fluxes of the organic compound up to 3300, 130 and 30 mg/m(2)h) and organic/air separation factors of 250, 6.3 and 38 were achieved for n-hexane, formaldehyde and benzene, respectively. (C) 2004 Elsevier B.V. All rights reserved.