화학공학소재연구정보센터
Chemical Engineering & Technology, Vol.23, No.2, 141-150, 2000
Extension of rapid sizing algorithm for shell-and-tube heat exchangers with tube-side pressure drop constraint and multipasses (Part B)
There are occasions in which process engineers need approximate estimates of the exchanger size rather than full detailed designs. These situations are often accompanied by a need for speed. This paper provides a simple procedure for exchanger sizing which is rapid and with reasonable accuracy. The methodology involved is described in detail here and it is shown that the procedure can be applied to pure counterflow and also for multipass exchangers.