화학공학소재연구정보센터
Separation Science and Technology, Vol.40, No.1-3, 419-431, 2005
Gas permeation testing results from the mixed waste focus area improved hydrogen getter program
The gas permeabilities of more than 20 polymers were measured using pure and mixed gas techniques. The motivation was to determine potential materials that could be used to protect hydrogen getter particles from poisons while permitting sufficient hydrogen rates to enable the getters use in TRUPACT types of containers. A rate of five barrers or larger is needed. Of the materials screened in the pure gas tests, more than 15 qualified. Nine materials qualified in the mixed gas tests, but of the nine only three had high CCl4 rejection rates and four others would greatly reduce the transport of the CCl4.