화학공학소재연구정보센터
Chemical Engineering Science, Vol.60, No.21, 5696-5704, 2005
A general correlation for pressure drop in a Kenics static mixer
A new pressure drop correlation in a Kenics static mixer has been developed. Pressure drop data were generated from computational fluid dynamics (CFD) calculations, avoiding the experimental limitations in obtaining comprehensive data enough for developing a reliable pressure drop correlation. Dimensional analysis reveals that the pressure drop characteristic of the Kenics static mixer can be described by three dimensionless groups, i.e., the friction factor, Reynolds number (Re), and aspect ratio of a mixing element (AR). A systematic graphical analysis led to a single master curve governing the pressure drop behavior of the Kenics static mixer, which had never been achieved before. We derived a pressure drop correlation fitting well with the obtained master curve in a general form into which the AR effect on the pressure drop is directly incorporated. Unlike the already existing correlations available in the literature, the correlation proposed in this study can cover the whole range of Re from laminar to turbulence. The reliability of the proposed correlation was validated by the comparison with various pressure drop data reported in the literature. (c) 2005 Elsevier Ltd. All rights reserved.