화학공학소재연구정보센터
Electrochimica Acta, Vol.51, No.20, 4210-4217, 2006
Modelling of the concentration-time relationship based on global diffusion-charge transfer parameters in a flow-by reactor with a 3D electrode
A concentration versus time relationship model based on the isothermal diffusion-charge transfer mechanism was developed for a flow-by reactor with a three-dimensional (3D) reticulated vitreous carbon (RVC) electrode. The relationship was based on the effectiveness factor (eta) which lead to the simulation of the concentration decay at different electrode polarisation conditions, i.e. -0.1, -0.3 and -0.59 V versus SCE; the charge transfer process was used for the former and mix and a mass transport control was used for the latter. Charge transfer and mass transport parameters were estimated from experimental data using Electrochemical Impedance Spectroscopy (EIS) and Linear Voltammetry (LV) techniques, respectively. (c) 2005 Elsevier Ltd. All rights reserved.