Applied Chemistry, Vol.11, No.1, 321-324, May, 2007
ZrCo 하이드라이드에서 흡장 속도와 탈장 속도 평가
Recovery and delivery rate of hydrogen from ZrCo hydride
Recovery and delivery rate of hydrogen from ZrCoH1.6 at different temperatures were measured. 19.7L of hydrogen at ~1bar was absorbed into a ZrCo of 160g at room temperature. 83%, 98%, 100% of hydrogen was absorbed in 10, 30, 60 minutes, respectively. Until 30 minutes of delivery, average delivery rate was measured to be 0.28Pam3/s at 250-350℃, 0.29Pam3/s at 275-350℃ and 0.45Pam3/s at 300-350℃. From this experiment, preheating temperature was found to be higher than 300℃. During repetition of delivery for 1350 sec and preheating for 450 sec at 350℃, average delivery rate was measured to be 0.32Pam3/s at the first delivery, 0.26Pam3/s at the second delivery and 0.22Pam3/s at the third delivery, respectively.