Chinese Journal of Chemical Engineering, Vol.6, No.3, 233-238, 1998
A general equation for calculating the 'true' height of transfer unit in extraction columns
Based on single drop mass transfer models and two phase flow equation, a general equation for calculating the 'true' height of transfer unit of extraction columns was derived and tested with four types of extraction columns with some different working systems. The calculated results fitted well with those obtained by experiments.