Chinese Journal of Chemical Engineering, Vol.7, No.4, 307-314, 1999
Runaway criterion in fixed bed catalytic reactors with radial temperature profile
The discrepancy between pseudo-homogeneous one-dimensional model and pseudohomogeneous two-dimensional model is studied. It is found that there are great differences between two models. This paper compares the maximum and minimum values of the radial temperature in the hot spot in case that a single exothermic reaction is carried out, a correlation is obtained with pseudo-homogeneous one-dimensional model to describe the entire reactor behavior. A new runaway criterion, based on the occurrence of inflection in the hot spot locus, is developed for the case of pseudo-homogeneous two-dimensional model. This criterion predicts the maximum allowable temperature for safe operation and the regions of runaway, respectively. The calculated results show that, compared with the results based on pseudo-homogeneous one-dimensional model, runaway will easily occur when the radial temperature gradient has to be considered.