Journal of Hazardous Materials, Vol.109, No.1-3, 13-21, 2004
Measurement and numerical analysis of flammability limits of halogenated hydrocarbons
Flammability limits measurement was made for a number of halogenated compounds by the ASHRAE method. Most of compounds measured are the ones for which discrepancy was noted between the literature values and predicted values of flammability limits. As a result, it has been found that most of the newly obtained values of flammability limits are not in accordance with the literature values. Numerical analysis was carried out for a set of flammability limits data including the newly obtained ones using a modified analytical method based on F-number scheme. In this method, fitting procedure was done directly to flammability limits themselves instead of fitting to F-number. After the fitting process, the average relative deviation between the observed and calculated values is 9.3% for the lower limits and 14.6% for the upper limits. (C) 2004 Elsevier B.V. All rights reserved.