화학공학소재연구정보센터
Color Research and Application, Vol.20, No.1, 44-49, 1995
RESULTS OF THE ASTM FIELD-TEST OF TRISTIMULUS WEIGHTING FUNCTIONS
In 1993, the American Society for Testing and Materials carried out a field test of newly calculated tristimulus weighting factors. These weighting factors had been calculated by a method proposed by Venable. The test also included a method of correction for bandpass dependence put forth by Stearns. The purpose of the trial was to assess the possible reduction in bandpass dependence introduced by each of these sets of weights. A large number of sets of spectral data were gathered from the cooperators in the field test. Results of integration by the various sets of tristimulus weighting factors were calculated A total of 15 120 color differences were calculated and statistics were derived to test the probable error resulting from each method of correction. Errors attributable to bandpass dependence were on the order of a few tenths to as much as one CIELAB unit when uncorrected weight sets were used. These errors could be reduced to a few hundreths of a CIELAB unit, and in some cases to a few thousandths of a unit, by employing one correcting strategy or the other. An overall mix of strategies was ultimately chosen to minimize the bandpass dependence over the entire range of weight sets. Utilizing this mixed strategy, the median error introduced into 10-nm integration by bandpass dependence was only 0.004 CIELAB units.