화학공학소재연구정보센터
Journal of Hazardous Materials, Vol.137, No.2, 666-671, 2006
Auto-ignition and upper explosion limit of rich propane-air mixtures at elevated pressures
The auto-ignition limits of propane-air mixtures at elevated pressures up to 15 bar and for concentrations from 10 mol% up to 70 mol% are investigated. The experiments are performed in a closed spherical vessel with a volume of 8 dm(3). The auto-ignition temperatures decrease from 300 degrees C to 250 degrees C when increasing the pressure from 1 bar to 14.5 bar. It is shown that the fuel concentration most sensitive to auto-ignition depends on initial pressure. A second series of experiments investigates the upper flammability limit of propane-air mixtures at initial temperatures up to 250 degrees C and pressures up to 30 bar near the auto-ignition area. Finally the propane auto-oxidation is modelled using several detailed kinetic reaction mechanisms and these numerical calculations are compared with the experimental results. (c) 2006 Elsevier B.V. All rights reserved.