화학공학소재연구정보센터
Energy Sources, Vol.18, No.1, 37-42, 1996
Design parameters of a solar-driven heat engine
Maximum power and efficiency are treated at the maximum power output of an internally and externally irreversible solar-driven power plant heat engine. It was found that the thermal efficiency depends on the cycle-irreversibility parameter for a given value of reservoir temperature ratio. It was also concluded that the external irreversibility parameter must be less than 1.0 for maximum power output.